Vinotemp WINE-MATE VINO-2500SSW Dokumentacja

Przeglądaj online lub pobierz Dokumentacja dla Nie Vinotemp WINE-MATE VINO-2500SSW. Vinotemp WINE-MATE VINO-2500SSW Specifications Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
w
w
w
w
w
w
.
.
w
w
i
i
n
n
e
e
m
m
a
a
t
t
e
e
.
.
c
c
o
o
m
m
Wall Split Cooling System
Installation, Operation & Care Manual
VINO-1500SSW VINO-2500SSW
w
w
w
w
w
w
.
.
v
v
i
i
n
n
o
o
t
t
e
e
m
m
p
p
.
.
c
c
o
o
m
m
R
R
e
e
a
a
d
d
a
a
n
n
d
d
s
s
a
a
v
v
e
e
t
t
h
h
e
e
s
s
e
e
i
i
n
n
s
s
t
t
r
r
u
u
c
c
t
t
i
i
o
o
n
n
s
s
Przeglądanie stron 0
1 2 3 4 5 6 ... 27 28

Podsumowanie treści

Strona 1 - Wall Split Cooling System

wwwwww..wwiinneemmaattee..ccoomm Wall Split Cooling System Installation, Operation & Care Manual VINO-1500SSW VINO-2500SSW wwwwww..vviinnoo

Strona 2 - Important Safety Information

- 9 -Care Guide In general, always unplug system or disconnect powe

Strona 3 - Table of Contents

- 10 -User’s Troubleshooting This Troubleshooting Chart is not prepar

Strona 4 - Features and Specifications

- 11 -high or not cooling and running continually b. Cellar too lar

Strona 5

- 12 -fan running but condensing unit not running b. Failed components

Strona 6 - Temperature and Humidity

- 13 -Installer’s Instruction Federal law requires that WINE-MATE spl

Strona 7

- 14 -CAUTION: Liquid and suction line locations may differ from what

Strona 8

- 15 -CAUTION: Low ambient condition kit is required if the installati

Strona 9

- 16 -3. Condensing Unit Installation CAUTION: If the condensing un

Strona 10 - Care Guide

- 17 -3 – Liquid Line or Suction Line; 4 - Pressure Control Back Posit

Strona 11 - User’s Troubleshooting

- 18 - Fig. 10 Condenser Fan Cycle Control 6. Piping and Evacuating

Strona 12

- 1 -Important Safety Information WARNING: • Do not use a ground fau

Strona 13

- 19 -Model No Line Set Liquid Line Suction Line Drain Line Recommend

Strona 14 - Installer’s Instruction

- 20 -6) Again, you must verify if the superheat at the evaporator un

Strona 15

- 21 -9) Low suction pressure and low head pressure Normal to high su

Strona 16

- 22 -Cellar Construction This is only a guide and shall be considere

Strona 17

- 23 -Electrical Wiring Diagrams CAUTION: • Hidden lines are the fi

Strona 18

- 24 - Fig. 14 Low Ambient Temperature VINO-1500~2500SSW-LA Electric

Strona 19

- 25 -Customer Support If you need further assistance, please contact

Strona 20

- 26 -Warranty Thank you for choosing a Vinotemp cooling unit. Ple

Strona 21

- 27 -VINOTEMP will, at its discretion, repair or replace the unit and

Strona 22

- 2 -Table of Contents Features & Specifications…………………….….………….

Strona 23 - Cellar Construction

- 3 -Features and Specifications • Wine-Mate wall split cooling syst

Strona 24 - Electrical Wiring Diagrams

- 4 -NOTE: To prepare rough-in, leave minimum 3” clearances for electr

Strona 25

- 5 -Temperature and Humidity 1. Use of the controller Fig. 2 Tempe

Strona 26 - Customer Support

- 6 -4) Alarm Signals The alarm codes are described as follows. MES

Strona 27 - Warranty

- 7 -5. How to calibrate the air temperature probe If the actual cel

Strona 28

- 8 -4) Press the “SET” key to display its value. 5) Use up/down keys

Komentarze do niniejszej Instrukcji